MV Roland Delmas

In 2004 the complete old Siemens Simos alarm system as well as the entire diesel control, including the power management system, were replaced on the Roland Delmas vessel.

Renewal of the alarm system with 140 analog and 290 binary measuring facilities in Antwerp
After the fire in the ECR
After the fire in the ECR
Disconnecting and Labeling
Disconnecting and Labeling
After the retrofit
After the retrofit
After the fire the badly damaged connection terminal was completely removed, the switchboard newly painted and all cables were tied to the system on new terminals.
PLC Stations 1+2
PLC Stations 1+2
PLC Station 1 with analog inputs
PLC Station 1 with analog inputs
Power Management
Power Management
The old Siemens Simos system has been replaced by a Schneider TSX-Premium PLC with three stations. Furthermore, one SYMAP BCG for each generator has been inserted for the diesel control, the generator protection and the power management.
ECR control panel
ECR control panel
Auxiliary Engines
Auxiliary Engines
Exhaust Gas Temperatue & ME-data
Exhaust Gas Temperatue & ME-data
Moreover, two 17'' touch panels in the ECR as well as an additional redundant 10.4'' touch panel for the emergency operation have been installed.
Further modification: graphic representation in the form of bar graphs; an alarm list; trend viewer; etc.